Title of article
Experimental study on porous current collectors of PEM electrolyzers
Author/Authors
Ito، نويسنده , , Hiroshi and Maeda، نويسنده , , Tetsuhiko and Nakano، نويسنده , , Akihiro and Hwang، نويسنده , , Chul Min and Ishida، نويسنده , , Masayoshi and Kato، نويسنده , , Atsushi and Yoshida، نويسنده , , Tetsuya، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
11
From page
7418
To page
7428
Abstract
Experimental study on proton exchange membrane (PEM) electrolyzer was carried out focusing on the effect of pore structural properties of current collectors, such as porosity and pore diameter. Various titanium (Ti)-felt substrates with different porosities and pore diameters (measured by capillary flow porometry) were used as the anode current collector. Results show that when the mean pore diameter of the current collector was larger than 10 μm, the electrolysis performance improved with decreasing pore diameter. In contrast, changes in porosity had no significant effect on the cell performance when the porosity exceeded 0.50. The flow pattern of two-phase flow in the flow channel was discussed in terms of its relationship to bubble size and to pore diameter of the current collector. Finally, correlation between the calculated membrane resistance and the measured pore diameter of the current collectors suggest that larger bubbles generated from larger pores tend to become long bubbles in the channel, thus hindering the water supply to the membrane.
Keywords
PEM electrolysis , Current collector , pore diameter , proton conductivity
Journal title
International Journal of Hydrogen Energy
Serial Year
2012
Journal title
International Journal of Hydrogen Energy
Record number
1671228
Link To Document