Title of article :
Heat extraction from supercritical water-cooled nuclear reactors for hydrogen production plants
Author/Authors :
Abedin، نويسنده , , Ali A.H. and Wang، نويسنده , , Z. and Rosen، نويسنده , , M.A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
8
From page :
16527
To page :
16534
Abstract :
Many current and future hydrogen production methods, such as steam methane reforming and thermochemical water splitting cycles, require large amounts of heat as the major energy input. Using nuclear heat is a promising option for reducing emissions of greenhouse gases and other pollutants, thereby helping achieve clean and sustainable future energy systems. Various heat transfer fluids are compared and evaluation criteria are proposed for the selection of a heat transfer fluid. It is determined that helium is a promising option due to it being inert and chemically stable and having good heat transfer properties. The intermediate heat exchanger for the heat extraction is analyzed and designed using the log mean temperature difference (LMTD) method with helium serving as the heat transfer fluid to extract heat from the supercritical water. It is found that if the heat extraction load is in the range of 100–330 MWth, which approximately corresponds to a hydrogen production range of 40–125 tonnes per day, then a multi-tube and single-shell counter flow heat exchanger with a shell diameter of 0.7–1.3 m and length of 6.7 m encapsulating 420–1600 tubes of 0.025 m diameter would be appropriate according to the practical working conditions on the shell and tube sides. The analysis also shows that the diameter of the heat exchanger does not depend strongly on the heat transfer load if the load is smaller than 330 MWth (125 tonnes H2/day). This provides flexibility in case adjustments to the heat extraction load become necessary. However, if the heat load is larger than 330 MWth, for example, 500 MWth for 200 tonnes hydrogen per day, then a multi-tube and single-shell counter flow heat exchanger is not appropriate because the length-to-diameter ratio is outside of the recommended range.
Keywords :
Shell and tube heat exchanger , Hydrogen production , Thermochemical hydrogen production , Cu–Cl hydrogen production cycle , LMTD method
Journal title :
International Journal of Hydrogen Energy
Serial Year :
2012
Journal title :
International Journal of Hydrogen Energy
Record number :
1673692
Link To Document :
بازگشت