Title of article
Determination of traces molybdenum by catalytic adsorptive stripping voltammetry
Author/Authors
Ensafi، نويسنده , , Ali A. and Khaloo، نويسنده , , Shokooh S.، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2005
Pages
8
From page
781
To page
788
Abstract
A reliable and very sensitive procedure for the determination of ultra trace of molybdenum is proposed. Molybdenum was determined by cathodic stripping differential pulse voltammetry based on the adsorption collection of the Mo(VI)–Tiron complex on a hanging mercury drop electrode (HMDE). The variation of peak current with pH, concentration of Tiron and chlorate, plus several instrumental parameters such as accumulation time, accumulation potential and scan rate, were optimized. Under optimized condition, the relationship between the peak current and molybdenum concentration is linear in the range of 0.010–21.0 ng ml−1. The limit of detection was found to be 0.006 ng ml−1. The relative standard deviation for 10 replicates determination of 0.6 and 10 ng ml−1 Mo(VI) is equal to 1.3 and 0.9%, respectively. The method was applied to the determination of molybdenum in river water, tap water, well water, plant foodstuff samples such as cucumber, tomato, carrot, and certified steel reference materials.
Keywords
Tiron , Molybdenum , Adsorption , Electrocatalysis , Stripping voltammetry
Journal title
Talanta
Serial Year
2005