• Title of article

    Amperometric determination of sodium hypochlorite at poly MnTAPP-nano Au film modified electrode

  • Author/Authors

    Thiagarajan، نويسنده , , Soundappan and Wu، نويسنده , , Zhi-Yuan and Chen، نويسنده , , Shen-Ming، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    7
  • From page
    322
  • To page
    328
  • Abstract
    Poly manganese tetra (o-amino phenyl) porphyrin (MnTAPP)-nano Au film was electrodeposited on glassy carbon electrode (GCE) and indium tin oxide coated glass electrode (ITO) using cyclic voltammetry (CV). Electrodeposited poly MnTAPP-nano Au modified electrodes have been characterized using scanning electron microscopy (SEM) and atomic force microscopy (AFM) techniques. Poly MnTAPP-nano Au film modified GCE found as electrochemically active and stable. Poly MnTAPP-nano Au modified GCE employed for the amperometric detection of sodium hypochlorite (NaOCl) in the linear range of 24 × 10−6–1.07 × 10−2 M. The proposed film holds the capacity to overcome the interference substances and showed the reduction current response for the NaOCl additions. In addition, the poly MnTAPP-nano Au film successfully exhibits the reduction current of NaOCl concentrations in the commercially available bleaching liquids, respectively.
  • Keywords
    Cyclic voltammetry , Poly MnTAPP , Amperometry , Sodium hypochlorite , Nano Au
  • Journal title
    Journal of Electroanalytical Chemistry
  • Serial Year
    2011
  • Journal title
    Journal of Electroanalytical Chemistry
  • Record number