• Title of article

    Square Wave Voltammetric detection of furan on platinum and platinum-based Screen Printed Electrodes

  • Author/Authors

    Falciola، نويسنده , , Luigi and Pifferi، نويسنده , , Valentina and Possenti، نويسنده , , Maria Luisa and Carrara، نويسنده , , Veronica، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    5
  • From page
    100
  • To page
    104
  • Abstract
    A rapid, precise and accurate electroanalytical methodology for the determination of furan, a possible human carcinogen, is proposed. The method is based on the use of Square Wave Voltammetry (SWV) on a platinum disk or on platinum based Screen Printed Electrodes, performed in acetonitrile with tetrabutylammonium perchlorate as supporting electrolyte. idation peak height or area present good linear relationship with the furan concentration in the range 1.5 × 10−5–1 × 10−3 M, with all sorts of electrodes, ensuring a detection limit of 1–2 × 10−5 M (1–2 ppm). V parameters optimization and the use of Nafion membrane to protect SPE from fouling and reference electrode damage are also discussed. plication in a complex matrix is performed.
  • Keywords
    furan , Square Wave Voltammetry , Platinum Electrode , Acetonitrile , Screen printed electrodes
  • Journal title
    Journal of Electroanalytical Chemistry
  • Serial Year
    2012
  • Journal title
    Journal of Electroanalytical Chemistry
  • Record number