• Title of article

    Behaviour of beam-to-column high strength steel endplate connections under fire conditions – Part 1: Experimental study

  • Author/Authors

    Qiang، نويسنده , , Xuhong and Bijlaard، نويسنده , , Frans S.K. and Kolstein، نويسنده , , Henk and Jiang، نويسنده , , Xu، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    16
  • From page
    23
  • To page
    38
  • Abstract
    In order to reveal more information and understanding on behaviour and failure mechanisms of high strength steel endplate connections under fire conditions, an experimental study has been carried out and presented in this paper. Full-scale tests on beam-to-column high strength steel endplate connections were conducted at elevated temperature 550 °C under steady state fire condition and at ambient temperature as reference. Further, their behaviour was compared with that of mild steel endplate connections. Moreover, the provisions of Eurocode 3 were validated with test results of high strength steel endplate connections. It is found that a proper thinner high strength steel endplate can enhance the connection’s rotation capacity both at ambient temperature and in fire (which guarantees the safety of an entire structure), and simultaneously achieve almost the same moment resistance with a mild steel endplate connection.
  • Keywords
    Beam-to-column connections , Endplate Connection , Experimental study , high strength steel , Structural fire performance
  • Journal title
    Engineering Structures
  • Serial Year
    2014
  • Journal title
    Engineering Structures
  • Record number

    1677318