Title of article :
Electrochemically reduced graphene oxide modified acetylene black paste electrode for the sensitive determination of bisphenol A
Author/Authors :
Deng، نويسنده , , Peihong and Xu، نويسنده , , Zhifeng and Kuang، نويسنده , , Yunfei، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
8
From page :
7
To page :
14
Abstract :
This paper has presented a novel strategy to carry out direct and sensitive determination of bisphenol A (BPA) based on the graphene modified acetylene black paste electrode (GR/ABPE). This modified electrode was obtained by one-step potentiostatic reduction of exfoliated graphene oxide sheets on the surface of ABPE. Due to the unique structure and extraordinary properties of GR and AB, the fabricated sensor displayed greatly improved voltammetric response to BPA compared with the conventional carbon paste electrode. Under the optimized conditions, the linear range for the detection of BPA was from 0.8 nM to 10.0 nM, 10.0 nM to 8.0 μM and 8.0 μM to 0.1 mM, with a detection limit (S/N = 3) of 0.6 nM. Additionally, this newly-developed method possesses some obvious advantages including extreme simplicity, rapid response and low cost. The practical analytical performance of the GR/ABPE was examined by evaluating the detection of BPA in plastic products with satisfied recovery.
Keywords :
Direct electrochemical reduction , Acetylene black paste electrode , Graphene oxide , Voltammetric sensor , BISPHENOL A
Journal title :
Journal of Electroanalytical Chemistry
Serial Year :
2013
Journal title :
Journal of Electroanalytical Chemistry
Record number :
1677503
Link To Document :
بازگشت