Title of article :
Determination of arsenic in sediments, coal and fly ash slurries after ultrasonic treatment by hydride generation atomic absorption spectrometry and trapping in an iridium-treated graphite tube
Author/Authors :
Vieira، نويسنده , , Mariana Antunes and Welz، نويسنده , , Bernhard and Curtius، نويسنده , , Adilson José، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
A simple and reliable method for the determination of arsenic in sediment and in coal without sample digestion, based on hydride generation from slurry samples is proposed. After grinding the samples to a particle size of ⩽50 μm, the sample powder was mixed with aqua regia and hydrofluoric acid in an ultrasonic bath for 30 min. After diluting the mixture with hydrochloric acid, the slurry was allowed to stand for 48 h, and an aliquot was used for hydride generation with sodium borohydride. More than 80% of the arsenic was leached to the aqueous phase under these conditions, except for one sediment sample with very high silica content. The generated arsine was collected in a graphite tube, treated with 0.5 mg of iridium as a permanent modifier, and the arsenic determination was carried out by electrothermal atomic absorption spectrometry. The same tube could be used for at least 160 cycles without any re-treatment. The greatest advantage of the method was that only a minimum of reagents and sample handling were required, reducing the risks of contamination and/or analyte loss. However, the addition calibration technique had to be used in order to obtain results within the 95% confidence level for 11 certified reference materials, 5 sediments, 5 coals and one coal fly ash. One certified sediment slurry was spiked with the analyte and the resulting addition calibration curve was used for the analysis of the certified sediments. Similarly, one certified coal was used to obtain the addition calibration curve for the coal and coal fly ash samples. The recoveries of the certified values, except for one sediment, were between 91 and 115%. The limits of detection in the samples were 0.54 and 0.7 μg g−1 for the coal and sediment samples, respectively, obtained for 1 ml of slurry containing 1 mg of sample.
Keywords :
sediment , Arsenic , Coal , ultrasonic treatment , Iridium modifier , Hydride generation electrothermal atomic absorption spectrometry
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy