Method development for the determination of thallium in coal using solid sampling graphite furnace atomic absorption spectrometry with continuum source, high-resolution monochromator and CCD array detector
Author/Authors
Silva، نويسنده , , Alessandra F and Borges، نويسنده , , Daniel L.G and Welz، نويسنده , , Bernhard and Vale، نويسنده , , Maria Goreti R. and Silva، نويسنده , , Mلrcia M and Klassen، نويسنده , , Aline and Heitmann، نويسنده , , Uwe، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
10
From page
841
To page
850
Abstract
The determination of thallium by graphite furnace atomic absorption spectrometry (GFAAS) is plagued by several difficult-to-control interferences. High-resolution continuum-source GFAAS, a technique not yet commercially available, was used to investigate and eliminate spectral interferences, and to develop a reliable method for the determination of thallium in coal using direct solid sampling. The resolution of 2.1 pm per pixel, and the display of the spectral environment ±0.2 nm on both sides of the analytical line were ideally suited for that purpose. The thallium signal was preceded by excessive non-specific absorption due to the coal matrix when pyrolysis temperatures ≤600 °C were used, and a characteristic molecular absorption with pronounced fine structure was following the atomic absorption. With a pyrolysis temperature of 700 °C the non-specific absorption at the beginning of the atomization stage could be eliminated, and using an atomization temperature of 1700 °C, and no modifier, the atomic absorption could be separated in wavelength and in time from the molecular structures, making possible an interference-free determination of thallium, using Pixel 260 at 276.8085 nm for background correction. The results obtained for 11 coal samples and one coal fly ash were in agreement at a 95% confidence level without a modifier, with palladium added in solution, and with ruthenium as permanent modifier, respectively, using aqueous standards for calibration. A characteristic mass of m0=12 pg and 5.5 pg was obtained with the center pixel only, and the center pixel ±1, respectively. The precision, expressed as relative standard deviation was typically better than 5%, and the limit of detection, based on three times the standard deviation of the coal with the lowest analyte content, was 0.01 μg g−1.
Keywords
Solid sample analysis , Thallium determination , Coal analysis , High-resolution continuum-source atomic absorption spectrometry , Electrothermal atomization
Journal title
Spectrochimica Acta Part B Atomic Spectroscopy
Serial Year
2004
Journal title
Spectrochimica Acta Part B Atomic Spectroscopy
Record number
1680249
Link To Document