Title of article :
Determination of lead, cadmium and mercury in blood for assessment of environmental exposure: A comparison between inductively coupled plasma–mass spectrometry and atomic absorption spectrometry
Author/Authors :
Palmer، نويسنده , , Christopher D. and Lewis Jr.، نويسنده , , Miles E. and Geraghty، نويسنده , , Ciaran M. and Barbosa Jr.، نويسنده , , Fernando and Parsons، نويسنده , , Patrick J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
A biomonitoring method for the determination of Pb, Cd, and Hg at background levels in whole blood by inductively coupled plasma-mass spectrometry is described. While this method was optimized for assessing Pb, Cd and Hg at environmental levels, it also proved suitable for assessing concentrations associated with occupational exposure. The method requires as little as 200 μl of blood that is diluted 1 + 49 for direct analysis in the inductively coupled plasma-mass spectrometer. Method performance is compared to well-established AAS methods. Initial method validation was accomplished using National Institute of Standards and Technology (NIST) Standard Reference Material 966, Toxic Metals in Bovine Blood. Method detection limits (3s) are 0.05 μg dl− 1 for Pb, 0.09 μg l− 1 for Cd; and 0.17 μg l− 1 for Hg. Repeatability ranged from 1.4% to 2.8% for Pb; 3% to 10% for Cd; and 2.6% to 8.8% for Hg. In contrast, AAS method detection limits were 1 μg dl− 1, 0.54 μg l− 1, and 0.6 μg l− 1, for Pb, Cd, and Hg, respectively. Further performance assessments were conducted over a 2-year period via participation in four international External Quality Assessment Schemes (EQAS) operated specifically for toxic metals in blood. This includes schemes operated by (a) the New York State Department of Healthʹs Wadsworth Center, Albany, NY, USA (b) L′Institut National de Santé Publique du Québec, Centre de Toxicologie du Québec, Canada, (c) Friedrich-Alexander University, Erlangen, Germany, and (d) the University of Surrey, Guildford, UK Trace Elements scheme. The EQAS data reflect analytical performance for blind samples analyzed independently by both inductively coupled plasma-mass spectrometry and AAS methods.
Keywords :
Blood , Lead , Cadmium , Atomic absorption spectrometry , Inductively coupled plasma–mass spectrometry
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy