Title of article :
Dry grinding kinetics of colemanite
Author/Authors :
Bozkurt، نويسنده , , V. and ضzgür، نويسنده , , I.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
5
From page :
88
To page :
92
Abstract :
The kinetics of batch dry grinding of colemanite from the feeds of sieve sizes − 2.360 + 1.700, − 1.700 + 1.180, − 1.180 + 0.850, − 0.850 + 0.600, − 0.600 + 0.425 and − 0.425 + 0.300 mm has been determined using a standard Bond mill. The specific rates of breakage (Si) and primary breakage distribution (Bi,j) values, called grinding breakage parameters, were determined for those feed size fractions. It was determined that breakage of colemanite follows a first-order behavior for all feed sizes. The specific rates of breakage (Si) values of colemanite increase with increasing feed size fractions. The specific rate of breakage parameters of colemanite were compared to quartz under the same experimental conditions and it was found that colemanite is broken faster than quartz in terms of the Si and aT values. Breakage function of colemanite was found to be non-normalizable (i.e. depended upon the feed particle size) similar to quartz ground under the same grinding conditions. In addition, colemanite produces finer material than quartz in terms of the γ value of Bi,j. It is also worth to mention here that to the authorsʹ knowledge there are no publications about the grinding kinetics of colemanite.
Keywords :
grinding kinetics , Colemanite , ball mill , Breakage parameters
Journal title :
Powder Technology
Serial Year :
2007
Journal title :
Powder Technology
Record number :
1693756
Link To Document :
بازگشت