Title of article :
Tracer percentage prediction of dive reflex samplers
Author/Authors :
Bensmann، نويسنده , , S. and Lockow، نويسنده , , Doris E. and Walzel، نويسنده , , P. and Weihs، نويسنده , , C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Abstract :
Instead of the frequently applied monochromatic light probes a whie light fibre optic system was employed at the Laboratory of Mechanical Process Design, TU Dortmund University, in order to exploit the color in formations for concentration measurements within bulk solid.
stem is applied to obtain local particle concentrations of blue- and red-colored quartz sand within the bed of a rotary drum. 16 solid mixtures with one or two particle sizes from 100 μm to 2000 μm and different species concentration were analyzed and the relationship between probe measurement values and red sand content was determined by statistical regression methods.
transformation of the data, linear models were found to derive the red sand content from given measurement values. Based thereupon, an all-purpose scheme for mono- and bi-disperse solid mixtures was developed and verified in an example with a mean error of 5%.
Keywords :
Bulk solids , Otical probe measurement , Solids mass fraction , statistics
Journal title :
Powder Technology
Journal title :
Powder Technology