• Title of article

    Standpipe models for diagnostics and control of a circulating fluidized bed

  • Author/Authors

    Ludlow، نويسنده , , J. Christopher and Panday، نويسنده , , Rupen and Shadle، نويسنده , , Lawrence J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    14
  • From page
    51
  • To page
    64
  • Abstract
    Two models for a Circulating Fluidized Bed (CFB) standpipe were formulated, implemented and validated to estimate critical CFB operational parameters. The first model continuously estimates standpipe bed height using incremental pressure measurements within the standpipe. The second model estimates variations in the void fraction along the standpipe using the Ergun equation in conjunction with the overall pressure drop across the bed, solids circulation rate and the standpipe aeration flows introduced at different locations of the pipe. The importance of different standpipe parameters obtained from these models is discussed in terms of successful operation of the overall CFB system. Finally, the applications of these models are shown in improving the solids circulation rate measurement and in calculating riser inventory.
  • Keywords
    Standpipe pressure profile , Circulating fluidized bed , Standpipe bed height , Solids circulation rate , Multi-phase gas solids flow
  • Journal title
    Powder Technology
  • Serial Year
    2013
  • Journal title
    Powder Technology
  • Record number