Title of article :
High temperature cement raw meal flowability
Author/Authors :
Maarup، نويسنده , , Claus and Hjuler، نويسنده , , Klaus and Dam-Johansen، نويسنده , , Kim، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
5
From page :
686
To page :
690
Abstract :
The flowability of cement raw meal is investigated at temperatures up to 850 °C in a specially designed monoaxial shear tester. Consolidation stresses of 0.94, 1.87 and 2.79 kPa are applied. The results show that the flowability is reduced as temperature is increased above 550 °C, indicated by increasing unconfined yield strength and reduced flowability factors. Deviation and reproducibility are acceptable for all temperatures except for 850 °C where belite formation and possibly calcination sinter the raw meal.
Keywords :
Monoaxial shear tester , high temperature , Cement raw meal , Powder flowability
Journal title :
Powder Technology
Serial Year :
2014
Journal title :
Powder Technology
Record number :
1704981
Link To Document :
بازگشت