• Title of article

    Rapid high-performance liquid chromatographic measurement of venlafaxine and O-desmethylvenlafaxine in human plasma: Application to management of acute intoxications

  • Author/Authors

    Matoga، نويسنده , , T and Pehourcq، نويسنده , , F and Titier، نويسنده , , Dumora، نويسنده , , F and Jarry، نويسنده , , C، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    6
  • From page
    213
  • To page
    218
  • Abstract
    Venlafaxine, a second-generation antidepressant, acts by inhibition of the reuptake of presynaptic noradrenaline and serotonin. The main metabolite, O-desmethylvenlafaxine was found biologically active. For toxicological purpose, a rapid specific and accurate RP-HPLC assay was developed for the simultaneous determination of venlafaxine and O-desmethylvenlafaxine in human plasma. A linear response was observed over the concentration range 0.2–4 μg/ml. A good accuracy (<8%) was achieved for all quality controls, with intra-day and inter-day variation coefficient less than 10%. Finally, no interference was observed with other psychotic drugs encountered in acute poisoning. This rapid method (run time <10 min) was used to manage four voluntary intoxications involving venlafaxine.
  • Keywords
    Venlafaxine , O-desmethylvenlafaxine
  • Journal title
    Journal of Chromatography B Biomedical Sciences and Applications
  • Serial Year
    2001
  • Journal title
    Journal of Chromatography B Biomedical Sciences and Applications
  • Record number

    1705644