Title of article :
Experiments and modeling of a vacuum membrane distillation for high saline water
Author/Authors :
Naidu، نويسنده , , Gayathri and Choi، نويسنده , , Yongjun and Jeong، نويسنده , , Sanghyun and Hwang، نويسنده , , Tae Mun and Vigneswaran، نويسنده , , Saravanamuthu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
A modified design vacuum membrane distillation (VMD) system with high saline water was evaluated using different operating conditions (sustainable low feed temperature and flow velocity). At high salinity, a permeate flux of 13.9 to 15.8 L m−2 h−1 was achieved. Increasing the salinity from 1 to 3 M NaCl reduced the permeate flux by 18–20%. An increase in bulk feed temperature (310.2–319.2 K) significantly increased the permeate flux by 64%. The increase in flow velocity (1.1 to 2.2 m s−1) in turn increased the permeate flux by 14–20%. Model fluxes predicted was a good fit to experimental fluxes (R2 ≥ 0.94).
Keywords :
high salinity , MODELING , Vacuum membrane distillation
Journal title :
Journal of Industrial and Engineering Chemistry
Journal title :
Journal of Industrial and Engineering Chemistry