Author/Authors :
Wang، نويسنده , , C.Y and Zhong، نويسنده , , S and Konstantinov، نويسنده , , K and Walter، نويسنده , , G and Liu، نويسنده , , H.K، نويسنده ,
Abstract :
Powder X-ray diffraction (XRD) is employed to identify the phase structure of Al-substituted nickel hydroxide, and its structural change after ageing treatment or charge/discharge cycles. The cell constants and the crystalline size of nickel hydroxides have been obtained by analysing the XRD pattern with Si as an internal standard. Results show that Al-substituted α-phase nickel hydroxide is very stable in strong alkaline medium even after 100 charge/discharge cycles.
Keywords :
XRD pattern , ?-Nickel hydroxide , Crystalline size , FWHM