Title of article
EMF measurements on mixed protonic/electronic conductors for hydrogen membrane applications
Author/Authors
Bentzer، نويسنده , , Henrik K. and Bonanos، نويسنده , , Nikolaos and Phair، نويسنده , , John W.، نويسنده ,
Issue Information
هفته نامه با شماره پیاپی سال 2010
Pages
7
From page
249
To page
255
Abstract
Electromotive force (EMF) measurements are often used to estimate the transport number of conducting species in ionic and mixed conductors. In this work, the applicability of the method to systems, where both protonic, oxide-ionic and electronic conduction is significant, was examined. The effect of electrode polarisation resistance, water vapour concentration and impurities was analysed. Samples of SrCe0.95Y0.05O3 − δ were prepared and used in a number of EMF measurements, including wet and dry hydrogen and oxygen concentration cells. It was found that concentration cells including water vapour gave large errors in the determination of the oxide-ionic transport number, but gave good estimates of the protonic transport number. The protonic transport number was estimated to around 0.80 at 600 °C, decreasing to around 0.65 at 800 °C, consistent with previous investigations on similar materials.
Keywords
Mixed conductors , Strontium cerate , EMF , Proton conductors