Title of article :
A portable bio-impedance system for monitoring lung resistivity
Author/Authors :
Zlochiver، نويسنده , , S. and Arad، نويسنده , , M. and Radai، نويسنده , , M.M. and Barak-Shinar، نويسنده , , D. and Krief، نويسنده , , H. and Engelman، نويسنده , , T. and Ben-Yehuda، نويسنده , , R. and Adunsky، نويسنده , , William A. and Abboud، نويسنده , , S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
8
From page :
93
To page :
100
Abstract :
The principles of a hybrid bio-impedance technique are implemented in a novel, lung resistivity monitoring system (“CardioInspect” Tel-Aviv University, Israel). The system is to be utilized in the clinic or at home, for daily monitoring of patients suffering from pulmonary edema. The developed system consists of an eight-electrode belt worn around the thorax, an electronic unit containing analog and digital boards, and a stand-alone DSP based system with a designated software to analyze the data. A Newton–Raphson algorithm based on the finite-volume method is employed for the optimization of the left and right lung resistivity values, making use of the voltage measurements retrieved from opposite current injections. In this preliminary study, 33 healthy volunteers were measured with the system during tidal respiration, yielding symmetric mean left and right lung resistivity values of (1205 ± 163, 1200 ± 165) (Ω cm). The system reproducibility was better than 2% for both within and between tests measurements, and no dependency between the reconstructed values and various anthropometric parameters was found.
Keywords :
EIT , Parameterized Newton–Raphson , ECG analysis , finite-volume method
Journal title :
Medical Engineering and Physics
Serial Year :
2007
Journal title :
Medical Engineering and Physics
Record number :
1729293
Link To Document :
بازگشت