Title of article
Energetic assessment of trunk postural modifications induced by a wearable audio-biofeedback system
Author/Authors
Giansanti، نويسنده , , D. and Dozza، نويسنده , , M. and Chiari، نويسنده , , L. and Maccioni، نويسنده , , G. and Cappello، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
7
From page
48
To page
54
Abstract
This paper investigates the trunk postural modifications induced by a wearable device which assesses the trunk sway and provides biofeedback information through sonification of trunk kinematics. The device is based on an inertial wearable sensing unit including three mono-axial accelerometers and three rate gyroscopes embedded and mounted orthogonally. The biofeedback device was tested on nine healthy subjects during quiet stance in different conditions of sensory limitation eyes closed on solid surface, eyes open on foam cushion surface, eyes closed on foam cushion surface. Five trials were performed for each condition; the order of the trials was randomized. The results reported in this paper show how subjects reduced their rotational kinetic energy by using the biofeedback information and how this reduction was related to the limitation of sensory information.
Keywords
Rotational kinetic energy , Inertial sensor , Auditory biofeedback , Balance , postural control , Prosthesis
Journal title
Medical Engineering and Physics
Serial Year
2009
Journal title
Medical Engineering and Physics
Record number
1730325
Link To Document