Title of article
Improved aorto-ventricular matching in ischemic dilated cardiomyopathy patients after surgical ventricular restoration
Author/Authors
Zhong، نويسنده , , Liang and Ghista، نويسنده , , Dhanjoo and Tan، نويسنده , , Ru San، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
7
From page
1120
To page
1126
Abstract
Scope
aper contains (i) derivation of the aorto-ventricular matching (AVM) index in terms of the ratio of aortic elastance and LV end-systolic elastance, Eaorta/Ees; (ii) procedure for determination of this index, by means of non-invasive measurements of auscultatory pressures, time-variation of blood volume ejected into the aorta, stroke volume and ejection fraction; (iii) results of improved AVM index evaluation in ischemic dilated cardiomyopathy (IDCM) patients following surgical ventricular restoration (SVR), as a result of reduced end-diastolic and end-systolic LV volumes and increased LV Ees.
ology
the ten recruited IDCM patients, four of them underwent surgical ventricular restoration (SVR) and coronary artery bypass graft (CABG), while six of them underwent CABG alone. All patients were studied by echocardiography pre- and 4 months post-operatively; LV volumes were determined by echo Doppler. LV end-systolic elastance Ees was determined from a derived expression, by employing blood pressure, stroke volume, ejection fraction, pre-ejection and systolic periods, and estimated normalized ventricular elastance at end-diastole, based on single-beat measurements. Aortic elastance Eaorta was determined by means of our modified single-beat method for determining aortic pressure profile.
s
CABG plus SVR group, the AVM index Eaorta/Ees was reduced by 35% from 0.93 ± 0.32 to 0.60 ± 0.33, consistent with improved aorto-ventricular matching. However, in the CABG alone group, the AVM index Eaorta/Ees decreased only 11% from 1.02 ± 0.24 to 0.91 ± 0.29.
sion
is shown to be increased value of LV Ees and a more favorable decreased value of AVM index in those IDCM patients who underwent SVR.
Keywords
Aorto-ventricular matching , Elastance , Echocardiography , coronary artery bypass graft , Surgical ventricular restoration , Ischemic dilated cardiomyopathy
Journal title
Medical Engineering and Physics