• Title of article

    Differences in Restenosis Rate With Different Drug-Eluting Stents in Patients With and Without Diabetes Mellitus: A Report From the SCAAR (Swedish Angiography and Angioplasty Registry)

  • Author/Authors

    Frِbert، نويسنده , , Ole and Lagerqvist، نويسنده , , Bo T. Carlsson، نويسنده , , Jِrg and Lindbنck، نويسنده , , Johan and Stenestrand، نويسنده , , Ulf and James، نويسنده , , Stefan K.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    8
  • From page
    1660
  • To page
    1667
  • Abstract
    Objectives m was to evaluate restenosis rate of drug-eluting stents (DES) in patients with and without diabetes mellitus (DM) in a real-world setting. ound em less effective in patients with DM. s AAR (Swedish Coronary Angiography and Angioplasty Registry) includes all patients undergoing percutaneous coronary intervention in Sweden. From April 1, 2004, to April 20, 2008, all restenoses detected at a subsequent angiography and all DES types implanted at more than 500 occasions were assessed using Cox regression. s ES types qualified for inclusion. In total, 35,478 DES were implanted at 22,962 procedures in 19,004 patients and 1,807 restenoses were reported over a mean 29 months follow-up. In the entire population, the restenosis rate per stent was 3.5% after 1 year and 4.9% after 2 years. The adjusted risk of restenosis was higher in patients with DM compared with that in patients without DM (relative risk [RR]: 1.23, 95% confidence interval [CI]: 1.10 to 1.37). In patients with DM, restenosis was twice as frequent with the zotarolimus-eluting Endeavor stent (Medtronic, Minneapolis, Minnesota) compared with that in the other DES types. The Endeavor stent and the sirolimus-eluting Cypher stent (Cordis, Johnson & Johnson, Miami, Florida) had higher restenosis rates in patients with DM compared with those in patients without DM (RR: 1.77, 95% CI: 1.29 to 2.43 and RR: 1.25, 95% CI: 1.04 to 1.51). Restenosis rate with the paclitaxel-eluting Taxus Express and Liberté (Boston Scientific, Natick, Massachusetts) stents was unrelated to DM. Mortality did not differ between different DES. sions osis rate with DES was higher in patients with DM compared with that in patients without DM. There seem to be important differences between different brands of DES.
  • Keywords
    drug-eluting stents , Angioplasty , Coronary Artery Disease , diabetes mellitus
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2009
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    1744483