Title of article :
Enoxaparin Anticoagulation Monitoring in the Catheterization Laboratory Using a New Bedside Test
Author/Authors :
Silvain، نويسنده , , Johanne and Beygui، نويسنده , , Farzin and Ankri، نويسنده , , Annick and Bellemain-Appaix، نويسنده , , Anne and Pena، نويسنده , , Ana and Barthelemy، نويسنده , , Olivier and Cayla، نويسنده , , Guillaume and Gallois، نويسنده , , Vanessa and Galier، نويسنده , , Sophie and Costagliola، نويسنده , , Dominique and Collet، نويسنده , , Jean-Philippe and Montalescot، نويسنده , , Gilles، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
9
From page :
617
To page :
625
Abstract :
Objectives tudy evaluated the ability of the bedside test Hemochron Jr. Hemonox (International Technidyne Corporation, Edison, New Jersey) to identify patients with insufficient anti-Xa activity level in the catheterization laboratory. ound uate anticoagulation in patients undergoing percutaneous coronary intervention (PCI) is associated with increased periprocedural ischemic events. s unselected patients undergoing catheterization and/or PCI, whole blood Hemonox clotting time (CT) and activated partial thromboplastin time (aPTT) were measured at baseline (T1) and 10 min after the intravenous administration of enoxaparin (T2) in patients receiving additional enoxaparin and compared with plasma chromogenic anti-Xa activity level. s values were 0.1 IU/ml (interquartile range [IQR]: 0.1 to 0.1 IU/ml) and 0.87 IU/ml (IQR: 0.74 to 1.03 IU/ml) for anti-Xa; 74 s (IQR: 70 to 81 s) and 143 s (IQR: 114 to 206 s) for Hemonox CT; and 44 s (IQR: 39 to 50 s) and 72 s (IQR: 58 to 93 s) for aPTT at T1 and T2, respectively. When using Hemonox CT to discriminate patients with anti-Xa level <0.5 IU/ml, the area under the receiver operating characteristic curve was 0.95 ± 0.01 (95% confidence interval [CI]: 0.93 to 0.97) versus 0.89 ± 0.01 (95% CI: 0.86 to 0.92) for aPTT. The threshold value of 120 s was associated with a 94.9% (95% CI: 91.1% to 97.4%) sensitivity and a 73.3% (95% CI: 67.6% to 78.5%) specificity to detect patients with inadequate anti-Xa level (<0.5 IU/ml) and positive predictive and negative predictive values of 73.9% (95% CI: 68.7% to 79.0%) and 94.78% (95% CI: 91.8% to 97.8%), respectively. sions x CT appears to be a fast and reliable bedside test for detecting patients insufficiently anticoagulated and needing adjustment of anticoagulation therapy with enoxaparin before PCI.
Keywords :
bedside test , percutaneous coronary intervention , ENOXAPARIN
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2010
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1746759
Link To Document :
بازگشت