Title of article :
Clinical Outcomes in Patients Undergoing Percutaneous Closure of Periprosthetic Paravalvular Leaks
Author/Authors :
Ruiz، نويسنده , , Carlos E. and Jelnin، نويسنده , , Vladimir and Kronzon، نويسنده , , Itzhak and Dudiy، نويسنده , , Yuriy and Del Valle-Fernandez، نويسنده , , Raquel and Einhorn، نويسنده , , Bryce N. and Chiam، نويسنده , , Paul T.L. and Martinez، نويسنده , , Claudia and Eiros، نويسنده , , Rocio and Roubin، نويسنده , , Gary C. Cohen، نويسنده , , Howard A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
8
From page :
2210
To page :
2217
Abstract :
Objectives rpose of this study was to evaluate the feasibility and efficacy of the percutaneous device closure of a consecutive series of patients with periprosthetic paravalvular leaks referred to our structural heart disease center with congestive heart failure and hemolytic anemia. ound ally significant periprosthetic paravalvular leak is an uncommon but serious complication after surgical valve replacement. Percutaneous closure has been utilized as an alternative to surgical repair of this defect in high-risk surgical patients. s s a retrospective review of 57 percutaneous paravalvular leak closures that were performed in 43 patients (67% male, mean age 69.4 ± 11.7 years) between April 2006 and September 2010. Integrated imaging modalities were used for the evaluation, planning, and guidance of the interventions. s e was successful in 86% of leaks and in 86% of patients. Twenty-eight of 35 patients improved by at least 1 New York Heart Association functional class. The percentage of patients requiring blood transfusions and/or erythropoietin injections post-procedure decreased from 56% to 5%. Clinical success was achieved in 89% of the patients in whom procedure was successful. The survival rates for patients at 6, 12, and 18 months after paravalvular leak closures were 91.9%, 89.2%, and 86.5%, respectively. Freedom from cardiac-related death at 42 months post-procedure was 91.9%. sions aneous closure of symptomatic paravalvular leaks, facilitated by integrated imaging modalities has a high rate of acute and long-term success and appears to be effective in managing symptoms of heart failure and hemolytic anemia.
Keywords :
paravalvular leak , Prosthetic valve , device closure
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2011
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1753224
Link To Document :
بازگشت