Title of article :
Transapical Aortic Valve Implantation: Incidence and Predictors of Paravalvular Leakage and Transvalvular Regurgitation in a Series of 358 Patients
Author/Authors :
Unbehaun، نويسنده , , Axel and Pasic، نويسنده , , Miralem and Dreysse، نويسنده , , Stephan and Drews، نويسنده , , Thorsten and Kukucka، نويسنده , , Marian and Mladenow، نويسنده , , Alexander and Ivanitskaja-Kühn، نويسنده , , Ekaterina and Hetzer، نويسنده , , Roland and Buz، نويسنده , , Semih، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
11
From page :
211
To page :
221
Abstract :
Objectives m of this study was to evaluate the results when the surgical concept of not accepting intraprocedural paravalvular leakage was applied for transcatheter aortic valve implantation (TAVI). ound rgical strategy of conventional aortic valve replacement does not accept paraprosthetic leakage and requires immediate action to eliminate it. However, paravalvular leakage is the major concern after TAVI. s l of 358 patients underwent transapical TAVI with balloon-expandable prostheses. The modified procedural strategy consisted of precise positioning of the prosthesis using a modified TAVI technique and immediate additional intraprocedural treatment to eliminate relevant paravalvular leakage. s n redilation of the transcatheter valve was performed in 18 patients (5%), and additional second valves were implanted in 13 (4%). At the end of the procedure, 186 patients (52%) had no paravalvular or transvalvular regurgitation. In the remaining 172 patients, paravalvular leakage was observed in 113 (32%), transvalvular leakage in 47 (13%), and both in 12 (3%). Leakage was trace in 88 patients (25%), mild in 82 (23%), and moderate in 2 (0.6%). Multivariate analysis identified male sex, New York Heart Association functional class IV, and no previous aortic valve replacement as predictors of post-procedural leakage. Cumulative survival was not dependent on post-procedural regurgitation rate. Overall mortality was 5 ± 1% at 30 days, 14 ± 2% at 6 months, 17 ± 2% at 1 year, and 33 ± 4% at 2 years. sions dified procedural strategy of transapical TAVI with a balloon-expandable prosthesis was associated with a low incidence of relevant prosthetic regurgitation.
Keywords :
aortic regurgitation , Predictors , transcatheter aortic valve implantation
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2012
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1753442
Link To Document :
بازگشت