Performance of 3-Dimensional Echocardiography in Measuring Left Ventricular Volumes and Ejection Fraction: A Systematic Review and Meta-Analysis
Author/Authors
Dorosz، نويسنده , , Jennifer L. and Lezotte، نويسنده , , Dennis C. and Weitzenkamp، نويسنده , , David A. and Allen، نويسنده , , Larry A. and Salcedo، نويسنده , , Ernesto E.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
10
From page
1799
To page
1808
Abstract
Objectives
imary aim of this systematic review is to objectively evaluate the test performance characteristics of three-dimensional echocardiography (3DE) in measuring left ventricular (LV) volumes and ejection fraction (EF).
ound
e its growing use in clinical laboratories, the accuracy of 3DE has not been studied on a large scale. It is unclear if this technology offers an advantage over traditional two-dimensional (2D) methods.
s
rched for studies that compared LV volumes and EF measured by 3DE and cardiac magnetic resonance (CMR) imaging. A subset of those also compared standard 2D methods with CMR. We used meta-analyses to determine the overall bias and limits of agreement of LV end-diastolic volume (EDV), end-systolic volume (ESV), and EF measured by 3DE and 2D echocardiography (2DE).
s
-three studies (1,638 echocardiograms) were included. The pooled biases ± 2 SDs for 3DE were −19.1 ± 34.2 ml, −10.1 ± 29.7 ml, and − 0.6 ± 11.8% for EDV, ESV, and EF, respectively. Nine studies also included data from 2DE, where the pooled biases were −48.2 ± 55.9 ml, −27.7 ± 45.7 ml, and 0.1 ± 13.9% for EDV, ESV, and EF, respectively. In this subset, the difference in bias between 3DE and 2D volumes was statistically significant (p = 0.01 for both EDV and ESV). The difference in variance was statistically significant (p < 0.001) for all 3 measurements.
sions
dimensional echocardiography underestimates volumes and has wide limits of agreement, but compared with traditional 2D methods in these carefully performed studies, 3DE is more accurate for volumes and more precise in all 3 measurements.
Keywords
real-time three-dimensional echocardiography , EJECTION FRACTION , left ventricular volumes , META-ANALYSIS , systematic review