Title of article :
Effect of diffusion coating of Nd on the corrosion resistance of biodegradable Mg implants in simulated physiological electrolyte
Author/Authors :
Levy، نويسنده , , Galit and Aghion، نويسنده , , Eli، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
7
From page :
8624
To page :
8630
Abstract :
The effect of diffusion coating of Nd on the corrosion performance of Mg–1.2%Nd–0.5%Y–0.5%Zr–0.4%Ca alloy (EW10X04) used as a new structural material for biodegradable implants was evaluated in a simulated physiological electrolyte. The initial Nd layer with a thickness of 1 μm was obtained by a physical vapor deposition process in an electron gun evaporator. This was followed by a diffusion coating process carried out at high temperature in a protective atmosphere. The microstructure of the diffusion coating system was examined using scanning electron microscopy, X-ray diffraction and X-ray photoelectron spectroscopy analysis. The corrosion resistance was evaluated by potentiodynamic polarization and electrochemical impedance spectroscopy in a simulated physiological electrolyte in the form of 0.9% NaCl solution saturated with Mg(OH)2. The results of the corrosion tests clearly demonstrated that the corrosion resistance of the alloy with the diffusion coating layer was significantly improved compared to the base alloy. This was mainly due to the relatively continuous network of the secondary passive phase Mg41Nd5 that acts as an effective corrosion barrier and the beneficial effect of enriching the oxide film with Nd and Nd oxides such as Nd2O3 and Nd6O11.
Keywords :
Magnesium , Diffusion coating , Biodegradable implants , Neodymiun
Journal title :
Acta Biomaterialia
Serial Year :
2013
Journal title :
Acta Biomaterialia
Record number :
1757495
Link To Document :
بازگشت