Title of article :
Autonomic Denervation Added to Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation: A Randomized Clinical Trial
Author/Authors :
Katritsis، نويسنده , , Demosthenes G. and Pokushalov، نويسنده , , Evgeny and Romanov، نويسنده , , Alexander and Giazitzoglou، نويسنده , , Eleftherios and Siontis، نويسنده , , George C.M. and Po، نويسنده , , Sunny S. and Camm، نويسنده , , A. John and Ioannidis، نويسنده , , John P.A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Abstract :
Objectives
m of this study was to investigate whether the combination of conventional pulmonary vein isolation (PVI) by circumferential antral ablation with ganglionated plexi (GP) modification in a single ablation procedure, yields higher success rates than PVI or GP ablation alone, in patients with paroxysmal atrial fibrillation (PAF).
ound
tional PVI transects the major left atrial GP, and it is possible that autonomic denervation by inadvertent GP ablation plays a central role in the efficacy of PVI.
s
l of 242 patients with symptomatic PAF were recruited and randomized as follows: 1) circumferential PVI (n = 78); 2) anatomic ablation of the main left atrial GP (n = 82); or 3) circumferential PVI followed by anatomic ablation of the main left atrial GP (n = 82). The primary endpoint was freedom from atrial fibrillation (AF) or other sustained atrial tachycardia (AT), verified by monthly visits, ambulatory electrocardiographic monitoring, and implantable loop recorders, during a 2-year follow-up period.
s
m from AF or AT was achieved in 44 (56%), 39 (48%), and 61 (74%) patients in the PVI, GP, and PVI+GP groups, respectively (p = 0.004 by log-rank test). PVI+GP ablation strategy compared with PVI alone yielded a hazard ratio of 0.53 (95% confidence interval: 0.31 to 0.91; p = 0.022) for recurrence of AF or AT. Fluoroscopy duration was 16 ± 3 min, 20 ± 5 min, and 23 ± 5 min for PVI, GP, and PVI+GP groups, respectively (p < 0.001). Post-ablation atrial flutter did not differ between groups: 5.1% in PVI, 4.9% in GP, and 6.1% in PVI+GP. No serious adverse procedure-related events were encountered.
sions
on of GP ablation to PVI confers a significantly higher success rate compared with either PVI or GP alone in patients with PAF. (Circumferential Versus Ganglionated Plexi Ablation for Atrial Fibrillation [AF]; NCT00671905)
Keywords :
Paroxysmal atrial fibrillation , atrial tachycardia , Catheter Ablation , ganglionated plexi , Implantable loop recorder , pulmonary vein isolation
Journal title :
JACC (Journal of the American College of Cardiology)
Journal title :
JACC (Journal of the American College of Cardiology)