Title of article :
Clinical Outcomes With Bioabsorbable Polymer- Versus Durable Polymer-Based Drug-Eluting and Bare-Metal Stents: Evidence From a Comprehensive Network Meta-Analysis
Author/Authors :
Palmerini، نويسنده , , Tullio and Biondi-Zoccai، نويسنده , , Giuseppe and Della Riva، نويسنده , , Diego and Mariani، نويسنده , , Andrea and Sabaté، نويسنده , , Manel and Smits، نويسنده , , Pieter C. and Kaiser، نويسنده , , Christoph and DʹAscenzo، نويسنده , , Fabrizio and Frati، نويسنده , , Giacomo and Mancone، نويسنده , , Massimo and Genereux، نويسنده , , Philippe and Stone، نويسنده , , Gregg W.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
9
From page :
299
To page :
307
Abstract :
Objectives tudy sought to investigate the relative safety and efficacy of bioabsorbable polymer (BP)-based biolimus-eluting stents (BES) versus durable-polymer (DP)-drug-eluting stents (DES) and bare-metal stents (BMS) by means of a network meta-analysis. ound s have suggested that BP-BES might reduce the risk of stent thrombosis (ST) and late adverse outcomes compared with first-generation DES. However, the relative safety and efficacy of BP-BES versus newer-generation DES coated with more biocompatible DP have not been investigated in depth. s ized controlled trials comparing BP-BES versus currently U.S.-approved DES or BMS were searched through MEDLINE, EMBASE, and Cochrane databases. Information on study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. s rom 89 trials including 85,490 patients were analyzed. At 1-year follow-up, BP-BES were associated with lower rates of cardiac death/myocardial infarction (MI), MI, and target vessel revascularization (TVR) than BMS and lower rates of TVR than fast-release zotarolimus-eluting stents. The BP-BES had similar rates of cardiac death/MI, MI, and TVR compared with other second-generation DP-DES but higher rates of 1-year ST than cobalt-chromium everolimus-eluting stents (CoCr-EES). The BP-BES were associated with improved late outcomes compared with BMS and paclitaxel-eluting stents, considering the latest follow-up data available, with nonsignificantly different outcomes compared with other DP-DES although higher rates of definite ST compared with CoCr-EES. sions s large-scale network meta-analysis, BP-BES were associated with superior clinical outcomes compared with BMS and first-generation DES and similar rates of cardiac death/MI, MI, and TVR compared with second-generation DP-DES but higher rates of definite ST than CoCr-EES.
Keywords :
bare-metal stent(s) , drug-eluting stent(s) , META-ANALYSIS , Stent thrombosis
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2014
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1757894
Link To Document :
بازگشت