Title of article :
Patient-Centered Imaging: Shared Decision Making for Cardiac Imaging Procedures With Exposure to Ionizing Radiation
Author/Authors :
Einstein، نويسنده , , Andrew J. and Berman، نويسنده , , Daniel S. and Min، نويسنده , , James K. and Hendel، نويسنده , , Robert C. and Gerber، نويسنده , , Thomas C. and Carr، نويسنده , , J. Jeffrey and Cerqueira، نويسنده , , Manuel D. and Cullom، نويسنده , , S. James and DeKemp، نويسنده , , Robert and Dickert، نويسنده , , Neal W. and Dorbala، نويسنده , , Sharmila and Fazel، نويسنده , , Reza and Garcia، نويسنده , , Ernest V. and Gibbons، نويسنده , , Raymond J. and Halliburton، نويسنده , , Sandra S. and Hausleiter، نويسنده , , Jِrg and Heller، نويسنده , , Gary V. and Jerome، نويسنده , , Scott and Lesser، نويسنده , , John R. and Raff، نويسنده , , Gilbert L. and Tilkemeier، نويسنده , , Peter and Williams، نويسنده , , Kim A. and Shaw، نويسنده , , Leslee J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
10
From page :
1480
To page :
1489
Abstract :
The current paper details the recommendations arising from an NIH-NHLBI/NCI-sponsored symposium held in November 2012, aiming to identify key components of a radiation accountability framework fostering patient-centered imaging and shared decision-making in cardiac imaging. Symposium participants, working in 3 tracks, identified key components of a framework to target critical radiation safety issues for the patient, the laboratory, and the larger population of patients with known or suspected cardiovascular disease. The use of ionizing radiation during an imaging procedure should be disclosed to all patients by the ordering provider at the time of ordering, and reinforced by the performing provider team. An imaging protocol with effective dose ≤3mSv is considered very low risk, not warranting extensive discussion or written informed consent. However, a protocol effective dose >20mSv was proposed as a level requiring particular attention in terms of shared decision-making and either formal discussion or written informed consent. Laboratory reporting of radiation dosimetry is a critical component of creating a quality laboratory fostering a patient-centered environment with transparent procedural methodology. Efforts should be directed to avoiding testing involving radiation, in patients with inappropriate indications. Standardized reporting and diagnostic reference levels for computed tomography and nuclear cardiology are important for the goal of public reporting of laboratory radiation dose levels in conjunction with diagnostic performance. The development of cardiac imaging technologies revolutionized cardiology practice by allowing routine, noninvasive assessment of myocardial perfusion and anatomy. It is now incumbent upon the imaging community to create an accountability framework to safely drive appropriate imaging utilization.
Keywords :
appropriate use , image quality , Imaging , Radiation safety
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2014
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1758351
Link To Document :
بازگشت