• Title of article

    Association Between Frequency of Atrial and Ventricular Ectopic Beats and Biventricular Pacing Percentage and Outcomes in Patients With Cardiac Resynchronization Therapy

  • Author/Authors

    Ruwald، نويسنده , , Martin H. and Mittal، نويسنده , , Suneet and Ruwald، نويسنده , , Anne-Christine and Aktas، نويسنده , , Mehmet K. and Daubert، نويسنده , , James P. and McNitt، نويسنده , , Scott and Al-ahmad، نويسنده , , Amin and Jons، نويسنده , , Christian and Kutyifa، نويسنده , , Valentina and Steinberg، نويسنده , , Jonathan S. and Wang، نويسنده , , Paul and Moss، نويسنده , , Arthur J. and Zareba، نويسنده , , Wojciech، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    11
  • From page
    971
  • To page
    981
  • Abstract
    AbstractBackground percentage of biventricular pacing is required for optimal outcome in patients treated with cardiac resynchronization therapy (CRT), but the influence of ectopic beats on the success of biventricular pacing has not been well established. ives tudy sought to determine if increased ectopic beats reduce the chance of high biventricular pacing percentage and are associated with subsequent adverse outcomes. s he MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy), 801 patients with an implanted CRT-defibrillator device with data available on biventricular pacing percentage and pre-implantation 24-h Holter recordings were included. Using logistic regression, we estimated the influence of ectopic beats on the percentage of biventricular pacing. Reverse remodeling was measured as reductions in atrial and left ventricular end-systolic volumes (LVESV) at 1 year. Cox models were used to assess the influence of ectopic beats on the outcomes of heart failure (HF) or death, ventricular tachyarrhythmias (VTAs), and death. s pre-implantation Holter recording, ectopic beats accounted for a mean 3.2 ± 5.5% of all beats. The probability of subsequent low biventricular pacing percentage (<97%) was increased 3-fold (odds ratio: 3.37; 95% confidence interval: 1.74 to 6.50; p < 0.001) in patients with 0.1% to 1.5% ectopic beats and 13-fold (odds ratio: 13.42; 95% confidence interval: 7.02 to 25.66; p < 0.001) in patients with >1.5% ectopic beats compared with those with <0.1% ectopic beats. Patients with ≥0.1% ectopic beats had significantly less reverse remodeling (percent reduction in LVESV 31 ± 15%) than patients with <0.1% ectopic beats (percent reduction in LVESV 39 ± 14%; p < 0.001). The risk of HF/death and VTA was increased significantly in those with 0.1% to 1.5% ectopic beats (hazard ratio: 3.13 and 1.84, respectively) and for >1.5% ectopic beats (hazard ratio: 2.38 and 2.74, respectively). sions vely low frequencies of ectopic beats (≥0.1%) dramatically increase the probability of low biventricular pacing (<97%), with reduced CRT efficacy by less reverse remodeling and higher risk of HF/death and VTA. This supports pre-implantation Holter monitoring of patients selected for CRT for optimal outcome. (MADIT-CRT: Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy; NCT00180271)
  • Keywords
    Biventricular pacing , cardiac resynchronization therapy , Ectopic beats , Holter monitoring , reverse remodeling , Prognosis
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2014
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    1759234