Author/Authors :
Ku?ba، نويسنده , , J?zef and Piszczek، نويسنده , , Grzegorz and Gryczynski، نويسنده , , Ignacy and Johnson، نويسنده , , Michael L. and Lakowicz، نويسنده , , Joseph R.، نويسنده ,
Abstract :
We used resonance energy transfer and frequency-domain fluorometry to measure slow donor to acceptor diffusion in viscous media. The frequency-domain RET data were analyzed using a new numerical algorithm for predicting the donor intensity decay in the presence of diffusion occurring within the donor decay time. By the use of a rhenium metal–ligand complex as a microsecond decay time donor we were able to measure mutual donor-to-acceptor diffusion coefficients as low as 2×10−8 cm2/s. The availability of microsecond decay time luminophores and appropriate theory suggests the use of diffusion-enhanced energy transfer for measurement of diffusive processes and structural dynamics in biological systems.