Title of article :
A new method for eliciting and studying H-reflexes in the human masseter
Author/Authors :
Sheila D. Scutter، نويسنده , , S.D. and Türker، نويسنده , , K.S. and Yang، نويسنده , , J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
6
From page :
371
To page :
376
Abstract :
A non-invasive method is presented for transmuscular stimulation of the masseteric nerve, using a frame to apply a cathode to the mandibular notch and an anode to the inside of the mouth. The H-reflex response was recorded using surface, macro and single motor-unit (SMU) electromyography (EMG) from the masseter. The latency of the reflex response representing the H-reflex in SMUs was determined from the cumulative sum of the peristimulus time histogram. This latency was then corrected using a spike-trigger averaging technique, where the SMU spikes were used as triggers and the macro EMG recording as the source. SMU latencies for the H-reflex in masseter were in the range 5.9–8.8 msec, whereas H-reflex latencies for surface EMG varied between 5.4 and 6.4 msec.
Keywords :
H-reflex , human , single motor units , Masseter
Journal title :
Archives of Oral Biology
Serial Year :
1997
Journal title :
Archives of Oral Biology
Record number :
1800662
Link To Document :
بازگشت