• Title of article

    Effects of Nd: and Ho:yttrium-aluminium-garnet lasers on human dentine fluid flow and dental pulp-chamber temperature in vitro

  • Author/Authors

    Goodis، نويسنده , , H.E. and White، نويسنده , , J.M. and Marshall Jr.، نويسنده , , G.W. and Yee، نويسنده , , K. and Fuller، نويسنده , , N. and Gee، نويسنده , , L. and Marshall، نويسنده , , S.J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    10
  • From page
    845
  • To page
    854
  • Abstract
    Dentine specimens were prepared from freshly extracted third molars and initial permeability measured. Each specimen was subjected to Nd:yttrium-aluminium-garnet (YAG) (1.06 or 1.32 μm wavelength) or Ho:YAG (2.10 μm wavelength) laser energy while temperatures in the pulp chambers were recorded. Permeability was again measured and the surfaces examined by scanning electron microscopy. Six crown segments were used for each laser variable and eight permeability measurements were taken before and eight after laser exposure, while temperature was recorded during treatment. All wavelengths reduced permeability but temperature rises were high enough to have caused pulpal damage, indicating that shorter treatment times and lower power settings may be necessary if used in vivo.
  • Keywords
    Dentine , Fetal Calf Serum , Permeability , Temperature , Laser
  • Journal title
    Archives of Oral Biology
  • Serial Year
    1997
  • Journal title
    Archives of Oral Biology
  • Record number