• Title of article

    Accuracy of Conventional and Digital Radiography in Detecting External Root Resorption

  • Author/Authors

    Mesgarani ، Abbas نويسنده Assistant Professor, Department of Endodontics, Faculty of Dentistry, Babol University of Medical Sciences, Babol-Iran. , , Haghanifar ، Sina نويسنده . Associate Professor, Department of Oral & Maxillofacial Radiology, Faculty of Dentistry, Babol University of Medical Sciences, Babol-Iran , , Ehsani، Maryam Maryam نويسنده Dental Materials Research Center, School of Dentistry, Babol University of Medical Sciences, Babol, Iran. Ehsani, Maryam Maryam , Dokhte Yaghub، Samereh نويسنده Dental School, Babol University of Medical Sciences, Babol, Iran; , , Bijani ، Ali نويسنده Non-Communicable Pediatric Diseases Research Center, Babol University of Medical Sciences, Babol, Iran ,

  • Issue Information
    فصلنامه با شماره پیاپی 0 سال 2014
  • Pages
    5
  • From page
    241
  • To page
    245
  • Abstract
    Introduction: External root resorption (ERR) is associated with physiological and pathological dissolution of mineralized tissues by clastic cells and radiography is one of the most important methods in its diagnosis. The aim of this experimental study was to evaluate the accuracy of conventional intraoral radiography (CR) in comparison with digital radiographic techniques, i.e. charge-coupled device (CCD) and photo-stimulable phosphor (PSP) sensors, in detection of ERR. Methods and Materials: This study was performed on 80 extracted human mandibular premolars. After taking separate initial periapical radiographs with CR technique, CCD and PSP sensors, the artificial defects resembling ERR with variable sizes were created in apical half of the mesial, distal and buccal surfaces of the teeth. Ten teeth were used as control samples without any resorption. The radiographs were then repeated with 2 different exposure times and the images were observed by 3 observers. Data were analyzed using SPSS version 17 and chi-squared and Cohen’s Kappa tests with 95% confidence interval (CI=95%). Result: The CCD had the highest percentage of correct assessment compared to the CR and PSP sensors, although the difference was not significant (P=0.39). It was shown that the higher dosage of radiation increases the accuracy of diagnosis; however, it was only significant for CCD sensor (P=0.02). Also, the accuracy of diagnosis increased with the increase in the size of lesion (P=0.001). Conclusion: Statistically significant difference was not observed for accurate detection of ERR by conventional and digital radiographic techniques.
  • Journal title
    Iranian Endodontic Journal (IEJ)
  • Serial Year
    2014
  • Journal title
    Iranian Endodontic Journal (IEJ)
  • Record number

    1815824