Title of article :
Parametric study of nitrided AISI 304 austenite stainless steel prepared by plasma immersion ion implantation
Author/Authors :
Liang، نويسنده , , J.H. and Wang، نويسنده , , C.S. and Tsai، نويسنده , , W.F. and Ai، نويسنده , , C.F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
This paper investigates the characteristics of plasma immersion nitrogen-ion implanted AISI 304 austenite stainless steel against such processing parameters as bias voltage (5–20 kV), substrate temperature (300–500 °C), and implantation fluence (1.4 × 1018–4.2 × 1018 cm− 2). Characteristics of the as-implanted specimens under investigation included elemental depth profile, hardness depth profile, crystallographic structure, and corrosion behavior and were determined using glow discharge spectrometry (GDS), the Vickers hardness tester, X-ray diffractometry (XRD), and the potentiodynamic polarization test, respectively. The results show that nitrogen depth profiles strongly depend on these processing parameters and closely relate to the corresponding chromium depth profiles. The hardness depth profiles increase and widen as substrate temperature, bias voltage, and implantation fluence increase. In particular, an improvement in hardness is accompanied by a reduction in corrosion resistance when substrate temperature reaches 500 °C. The corrosion-resistance degrader, CrN, precipitates as substrate temperature exceeds 450 °C, a phenomenon which is clearly evident in the chromium depth profiles as well as the XRD results.
Keywords :
Plasma immersion ion implantation , Hardness , Corrosion , Nitridation
Journal title :
Surface and Coatings Technology
Journal title :
Surface and Coatings Technology