Title of article :
SIMS studies of titanium biomaterial hydrogenation after magnetoelectropolishing
Author/Authors :
Hryniewicz، نويسنده , , Tadeusz and Konarski، نويسنده , , Piotr and Rokicki، نويسنده , , Ryszard and Valicek، نويسنده , , Jan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Abstract :
Hydrogenation of the commercial purity (99%) CP Titanium Grade 2 biomaterial was investigated using the secondary ion mass spectrometry (SIMS) after two finishing electrochemical operations: standard electropolishing (EP), and magnetoelectropolishing (MEP). The SIMS depth profile analyses were carried out right after electropolishing, and again one month later. The mass spectrograms of secondary positive and negative ions were recorded. SIMS spectra reveal higher emission of positive O+, Ti+ and TiO+ secondary ions which corresponds to higher oxidation of MEP sample. Negative spectra show higher concentration of compounds containing carbon on MEP sample than those of EP sample. Lower content of hydrogen in the near-surface layers in the MEP sample right after the process was revealed. It was found that the concentrations of oxygen and hydrogen alter in time. One month of storage in air causes the contents of hydrogen in EP and MEP samples to be equalized. The SIMS studies performed after a one month period show that the differences in hydrogen contents between EP and MEP samples are not significant.
Keywords :
Titanium biomaterial , Magnetoelectropolishing (MEP) , Hydrogenation , SIMS depth profile analysis
Journal title :
Surface and Coatings Technology
Journal title :
Surface and Coatings Technology