Title of article
DOSIMETRIC EVALUATION OF A NEWLY DEVELOPED RADIOCHROMIC
Author/Authors
AKHAVAN، A نويسنده Radiation Applications Research School, Nuclear Science and Technology Research Institute , , SOHRABPOUR، M نويسنده Department of Energy Engineering, Sharif University of Technology, Tehran, I. R. of Iran , , SHARIFZADEH، M نويسنده Radiation Applications Research School, Nuclear Science and Technology Research Institute ,
Issue Information
فصلنامه با شماره پیاپی 0 سال 2008
Pages
4
From page
398
To page
401
Abstract
In order to improve the performance of a newly developed radiochromic film, GIC-79, some
dosimetric characteristics of this film have been studied based on relevant standard practice. The present
study describes some parameters that may affect the dosimeter response before, during, and after irradiation.
The effect of absorbed dose rate on dosimeter response was determined by irradiating dosimeters at low
absorbed dose rates with gamma rays. Calibration irradiations of dosimeters were performed with both
gamma rays and also electrons to determine the effect of large difference absorbed dose rates on dosimeter
response. In addition, post irradiation stability was obtained and also the temperature and humidity effects on
the dosimeter response during the storage time prior to irradiation and post irradiation have been investigated.
Journal title
Iranian Journal of Science and Technology Transaction A: Science
Serial Year
2008
Journal title
Iranian Journal of Science and Technology Transaction A: Science
Record number
1828006
Link To Document