Title of article
Vessel diameter measurements in gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries
Author/Authors
Westenberg، نويسنده , , Jos J.M and van der Geest، نويسنده , , Rob J. and Wasser، نويسنده , , Martin N.J.M. and van der Linden، نويسنده , , Edwin L. and van Walsum، نويسنده , , Theo and van Assen، نويسنده , , Hans C. and de Roos، نويسنده , , Albert and Vanderschoot، نويسنده , , Jan and Reiber، نويسنده , , Johan H.C.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
10
From page
13
To page
22
Abstract
In this study, the possibilities for quantification of vessel diameters of peripheral arteries in gadolinium contrast-enhanced magnetic resonance angiography (Gd CE MRA) were evaluated. Absolute vessel diameter measurements were assessed objectively and semi-automatically in maximum intensity projections (MIPs) of contrast-enhanced T1-weighted 3D spoiled gradient-echo datasets, studied with digital subtraction techniques. In vivo, the complete peripheral arterial bed of six patients was studied, from the aorto-iliac bifurcation down to the distal run-off. By measuring the signal intensity (SI) over the lumen of a vessel in the MIP, an SI-plot was obtained. Next, the vessel boundaries were determined using a threshold algorithm; from these boundary points individual diameter values could be obtained along the trajectory of the vessel. In an in vitro study, an optimal threshold value of 30% of the range of SI-values between the background and the maximal SI in the vessel was obtained for accurate diameter measurement in Gd CE MRA (i.e., full-width 30%-maximum). Furthermore, the relationship between the accuracy of these measurements and the scan resolution was investigated. Accuracy was found to be acceptable (i.e., less than 10% over/underestimation) for vessel sizes covering at least 3 pixels. In six patients, diameters were measured in MIPs of the total datasets (i.e., DT) as well as in selective MIPs of the clipped datasets (i.e., DS) (n = 209). DT and DS were statistically significantly correlated (p < 0.01) with a Pearson correlation coefficient rP = 0.98. Measurements in the total MIPs yielded statistically significant (p < 0.01) smaller diameter values compared with measurements in selective MIPs, with a mean difference of 0.15 mm. Diameter values from the selective MIPs of the aorto-iliac arteries were also compared with diameter values measured at corresponding anatomic positions in X-ray angiograms of these patients (i.e., DX) (n = 70). DX and DS were statistically significantly correlated (p < 0.01) with a Pearson correlation coefficient rP = 0.92. Diameters measured in the selective MIPs were smaller than those measured in the X-ray angiograms (mean difference 0.49 mm) and this difference was statistically significant (p < 0.01). In conclusion, diameter values can be evaluated accurately in MIPs of vessels with at least 3 pixels in diameter, using the full-width 30%-maximum criterion.
Keywords
Quantification , Magnetic resonance angiography , Gadolinium contrast-enhanced , Peripheral arteries
Journal title
Magnetic Resonance Imaging
Serial Year
2000
Journal title
Magnetic Resonance Imaging
Record number
1830453
Link To Document