Title of article :
Gravity-dependent perfusion of the lung demonstrated with the FAIRER arterial spin tagging method
Author/Authors :
Keilholz، نويسنده , , Shella D. and Knight-Scott، نويسنده , , Jack and Christopher، نويسنده , , John M. and Mai، نويسنده , , Vu M. and Berr، نويسنده , , Stuart S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
7
From page :
929
To page :
935
Abstract :
Magnetic resonance imaging of lung perfusion using an arterial spin tagging (AST) sequence called flow sensitive alternating inversion recovery with an extra RF pulse (FAIRER) was performed in the left and right lateral positions in five volunteers. Coronal slices were obtained and the average intensity of each lung was measured. In both positions, an increase in the intensity of the dependent lung was found (229% for left lateral, 40% for right lateral). No change was seen along an isogravitational plane. Lung volumes were measured in each position to account for the compression of the lungs by the heart. This effect was found to be symmetric and did not contribute to the perfusion gradient. This demonstrates that AST is sensitive to gravity-dependent perfusion gradients in the lung.
Keywords :
Lung MRI , Pulmonary perfusion , Gravity-dependent perfusion
Journal title :
Magnetic Resonance Imaging
Serial Year :
2001
Journal title :
Magnetic Resonance Imaging
Record number :
1831125
Link To Document :
بازگشت