Author/Authors :
Ueda، نويسنده , , Atsushi and Yokoyama، نويسنده , , Hidekatsu and Nagase، نويسنده , , Sohji and Hirayama، نويسنده , , Aki and Koyama، نويسنده , , Akio and Ohya، نويسنده , , Hiroaki and Kamada، نويسنده , , Hitoshi، نويسنده ,
Abstract :
The kinetics of a nitroxide radical in the renal parenchyma and pelvis in rats were investigated by employing an in vivo EPR imaging system equipped with a surface-coil-type resonator (SCR). The exposed kidney of a living rat was inserted into the single-turn coil of the SCR, with the renal major axis aligned with the direction of alternative magnetic field (B1). After the injection of nitroxide radical via the tail vein, EPR measurements were repeated. From the temporal EPR images of the kidney on the 2-D projection to the plane which is perpendicular to the direction of B1, the decay rate of nitroxide radical in the renal parenchyma and pelvis was estimated. The parenchymal decay rate was found to be significantly shorter than that for the pelvis.