Title of article
What is the recall rate of breast MRI when used for screening asymptomatic women at high risk?
Author/Authors
Warren، نويسنده , , Ruth M.L. and Pointon، نويسنده , , Linda and Caines، نويسنده , , Rebecca and Hayes، نويسنده , , Carmel and Thompson، نويسنده , , Deborah and Leach، نويسنده , , Martin O.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
9
From page
557
To page
565
Abstract
Breast screening acceptability is dependent on sensitivity and recall rate. We aimed to establish the recall rate for MRI and mammography, separately and together, when screening a cohort of women at high genetic risk. Women aged 35–49 years in the MARIBS study form the cohort. We analysed the recall rate, the number of extra tests and their effectiveness. Wilcoxon Rank test was used to estimate the effect of age and logistic regression with robust variance the effect of mammographic density on recall rates.
rst 726 screening studies took place in 415 women. Following 86 of these recall occurred, comprising 140 additional investigations. 28 of the cases were resolved without further MRI, and 18 women had more than 2 additional tests. Neither age nor mammographic density was associated with recall. MRI had a recall of rate of 10.19%, and mammography 4.00%. The two techniques largely recalled different cases and 10 cases only (11.62% of those recalled) were abnormal by both tests. The two together had a recall rate of 11.85%. Recall rates varied widely between centres of the study.
MRI in asymptomatic high-risk women age 35–49 years largely recalls different women from mammography. The combined figure of approximately 12% may be acceptable for screening and will be useful for planning similar studies.
Keywords
MAGNETIC RESONANCE IMAGING , Screening , Breast MR , High-risk , family history , breast cancer