• Title of article

    Detection of focal liver lesions in unenhanced and ferucarbotran-enhanced magnetic resonance imaging: a comparison of T2-weighted breath-hold and respiratory-triggered sequences

  • Author/Authors

    Rief، نويسنده , , Matthias and Wagner، نويسنده , , Moritz and Franiel، نويسنده , , Tobias and Bresan، نويسنده , , Viola and Taupitz، نويسنده , , Matthias and Klessen، نويسنده , , Christian W. Hamm، نويسنده , , Bernd and Asbach، نويسنده , , Patrick، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    7
  • From page
    1223
  • To page
    1229
  • Abstract
    Purpose estigate the image quality and detection rate of focal liver lesions by comparing a T2-weighted breath-hold single-shot sequence and a T2-weighted high spatial resolution fast spin-echo sequence with respiratory triggering via unenhanced and superparamagnetic iron oxide (SPIO)-enhanced liver imaging. als and Methods udy was approved by the local ethical review board; informed consent was waived. Liver-lesion contrast was measured and a qualitative consensus evaluation of image quality and lesion detection was performed in 42 consecutive patients using a 1.5-T MR system. s ver-lesion contrast was significantly higher (P<.05) for the respiratory-triggered sequence compared to the breath-hold sequence regarding unenhanced and SPIO-enhanced imaging. The respiratory-triggered sequences revealed significantly higher image quality scores as well as higher numbers of detected liver lesions compared to the breath-hold sequence on unenhanced and SPIO-enhanced imaging. The SPIO contrast did not significantly improve the number of detected lesions on the respective sequences (P>.05). sion d that respiratory-triggered fast spin-echo sequences produce a higher image quality and a more precise liver-lesion detection rate thereby justifying the increased acquisition time necessary for this method.
  • Keywords
    Liver imaging , Lesion detection , Respiratory triggering , SPIO
  • Journal title
    Magnetic Resonance Imaging
  • Serial Year
    2009
  • Journal title
    Magnetic Resonance Imaging
  • Record number

    1832899