Title of article :
Evaluation of preprocessing steps to compensate for magnetic field distortions due to body movements in BOLD fMRI
Author/Authors :
Barry، نويسنده , , Robert L. and Williams، نويسنده , , Joy M. and Klassen، نويسنده , , L. Martyn and Gallivan، نويسنده , , Jason P. and Culham، نويسنده , , Jody C. and Menon، نويسنده , , Ravi S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
10
From page :
235
To page :
244
Abstract :
Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is currently the dominant technique for non-invasive investigation of brain functions. One of the challenges with BOLD fMRI, particularly at high fields, is compensation for the effects of spatiotemporally varying magnetic field inhomogeneities (ΔB0) caused by normal subject respiration and, in some studies, movement of the subject during the scan to perform tasks related to the functional paradigm. The presence of ΔB0 during data acquisition distorts reconstructed images and introduces extraneous fluctuations in the fMRI time series that decrease the BOLD contrast-to-noise ratio. Optimization of the fMRI data-processing pipeline to compensate for geometric distortions is of paramount importance to ensure high quality of fMRI data. To investigate ΔB0 caused by subject movement, echo-planar imaging scans were collected with and without concurrent motion of a phantom arm. The phantom arm was constructed and moved by the experimenter to emulate forearm motions while subjects remained still and observed a visual stimulation paradigm. These data were then subjected to eight different combinations of preprocessing steps. The best preprocessing pipeline included navigator correction, a complex phase regressor and spatial smoothing. The synergy between navigator correction and phase regression reduced geometric distortions better than either step in isolation and preconditioned the data to make them more amenable to the benefits of spatial smoothing. The combination of these steps provided a 10% increase in t-statistics compared to only navigator correction and spatial smoothing and reduced the noise and false activations in regions where no legitimate effects would occur.
Keywords :
Echo-planar imaging , preprocessing , Body movements , Geometric distortions , Spatial smoothing , Functional magnetic resonance imaging , Phase regression , Navigator correction
Journal title :
Magnetic Resonance Imaging
Serial Year :
2010
Journal title :
Magnetic Resonance Imaging
Record number :
1832950
Link To Document :
بازگشت