Title of article :
Limitations of the permeability-limited compartment model in estimating vascular permeability and interstitial volume fraction in DCE-MRI
Author/Authors :
Correia Carreira، نويسنده , , Guido and Gemeinhardt، نويسنده , , Ole and Gorenflo، نويسنده , , Rudolf and Beyersdorff، نويسنده , , Dirk and Franiel، نويسنده , , Tobias and Plendl، نويسنده , , Johanna and Lüdemann، نويسنده , , Lutz، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
11
From page :
639
To page :
649
Abstract :
Dynamic contrast-enhanced magnetic resonance imaging commonly uses compartment models to estimate tissue parameters in general and perfusion parameters in particular. Compartment models assume a homogeneous distribution of the injected tracer throughout the compartment volume. Since tracer distribution within a compartment cannot be assessed, the parameters obtained by means of a compartment model might differ from the actual physical values. ork systematically examines the widely used permeability-surface-limited one-compartment model to determine the reliability of the parameters obtained by comparing them with their actual values. A computer simulation was used to model spatial tracer distribution within the interstitial volume using diffusion of contrast agent in tissue. Vascular parameters were varied as well as tissue parameters. The vascular parameters used were capillary radius (4 and 12 μm), capillary permeability (from 0.03 to 3.3 μm/s) and intercapillary distances from 30 to 300 μm. The tissue parameters used were tortuosity (λ), porosity (α) and interstitial volume fraction (ve). sults suggest that the permeability-surface-limited compartment model generally underestimates capillary permeability for capillaries with a radius of 4 μm by factors from ≈0.03 for α=0.04, to ≈ 0.1 for α=0.2, to ≈ 0.5 for α=1.0. An overestimation of actual capillary permeability for capillaries with a radius of 12 μm by a factor of ≥1.3 was found for α=1.0, while α=0.2 yielded an underestimation by a factor of ≈0.3 and α=0.04 by a factor of ≈ 0.03. The interstitial volume fraction, ve, obtained by the compartment model differed with increasing intercapillary distances and for low vessel permeability, whereas ve was found to be estimated approximately accurately for P=0.3 μm/s and P=3.3 μm/s for vessel distances <100 μm.
Keywords :
Capillary permeability , interstitial volume , Tofts model , Compartment model , DCE-MRI , Neoplasm
Journal title :
Magnetic Resonance Imaging
Serial Year :
2011
Journal title :
Magnetic Resonance Imaging
Record number :
1833152
Link To Document :
بازگشت