Title of article :
Wireless MR tracking of interventional devices using phase-field dithering and projection reconstruction
Author/Authors :
Rube، نويسنده , , Martin A. and Holbrook، نويسنده , , Andrew B. and Cox، نويسنده , , Benjamin F. and Houston، نويسنده , , J. Graeme and Melzer، نويسنده , , Andreas، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
9
From page :
693
To page :
701
Abstract :
AbstractPurpose tracking is crucial for interventional MRI (iMRI) because conventional device materials do not contribute to the MR signal, may cause susceptibility artifacts and are generally invisible if moved out of the scan plane. A robust method for wireless tracking and dynamic guidance of interventional devices equipped with wirelessly connected resonant circuits (wRC) is presented. s oposed method uses weak spatially-selective excitation pulses with very low flip angle (0.3°), a Hadamard multiplexed tracking scheme and employs phase-field dithering to obtain the 3D position of a wRC. RF induced heating experiments (ASTM protocol) and balloon angioplasties of the iliac artery were conducted in a perfused vascular phantom and three Thiel soft-embalmed human cadavers. s tip tracking was interleaved with various user-selectable fast pulse sequences receiving a geometry update from the tracking kernel in less than 30 ms. Integrating phase-field dithering significantly improved our tracking robustness for catheters with small diameters (4–6 French). The volume root mean square distance error was 2.81 mm (standard deviation: 1.31 mm). No significant RF induced heating (< 0.6 °C) was detected during heating experiments. sion ip tracking approach provides flexible, fast and robust feedback loop, intuitive iMRI scanner interaction, does not constrain the physician and delivers very low specific absorption rates. Devices with wRC can be exchanged during a procedure without modifications to the iMRI setup or the pulse sequence. A drawback of our current implementation is that position information is available for a single tracking coil only. This was satisfactory for balloon angioplasties of the iliac artery, but further studies are required for complex navigation and catheter shapes before animal trials and clinical application.
Keywords :
Interventional MRI , MR tip tracking , MR catheters , Phase-field dithering , balloon angioplasty , MRI-guided interventions , Resonant markers
Journal title :
Magnetic Resonance Imaging
Serial Year :
2014
Journal title :
Magnetic Resonance Imaging
Record number :
1834305
Link To Document :
بازگشت