Title of article :
Automated assessment of myocardial SPECT perfusion scintigraphy: A comparison of different approaches of case-based reasoning
Author/Authors :
Khorsand، نويسنده , , Aliasghar and Graf، نويسنده , , Senta and Sochor، نويسنده , , Heinz and Schuster، نويسنده , , Ernst and Porenta، نويسنده , , Gerold، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
SummaryObjective
tudy compared the diagnostic accuracy of different approaches of case-based reasoning (CBR) for the assessment of coronary artery disease (CAD) using thallium-201 myocardial perfusion scintigraphy in comparison with coronary angiography.
s and material
ch scintigraphic image set, regional myocardial tracer uptake was obtained by polar map analysis. CBR algorithms based on a similarity measure were employed to identify similar scintigraphic images within the case library, where each case contained the scintigraphic data together with results of coronary angiography. The angiographic data of retrieved cases were then used to determine whether significant CAD was present in one of the major coronary arteries. Three different approaches of CBR were compared: (1) case retrieval based on a global comparison of polar map data (GLOB), (2) case retrieval based on a territorial comparison of polar map data (TER), and (3) case retrieval based on a comparison of a given case with eight sub-libraries classified according to the involvement of the three major coronary vessels using a group similarity measure (GROUP). Two matching algorithms the best-match approach and an adapted retrieving approach were combined with all three case retrieval methods and their influence on the diagnostic accuracy were investigated.
s
erall detection of significant CAD, the best-match approach of both TER and GROUP retrieval methods showed a higher diagnostic accuracy than the GLOB retrieval method (75% and 77% versus 70%, respectively). ROC analysis for the adapted retrieving approach showed a similar diagnostic accuracy for all three methods with an area under the curve of 0.79, 0.8, and 0.8 for GLOB, TER, and GROUP, respectively.
sion
served improvement in the diagnostic accuracy by the new approaches may lead to further improvements of CBR systems, which have the potential to offer valuable decision support for human readers, especially for less experienced investigators.
Keywords :
SPECT , case-based reasoning , Myocardial perfusion , Similarity measure
Journal title :
Artificial Intelligence In Medicine
Journal title :
Artificial Intelligence In Medicine