• Title of article

    Cardiac Valve Prostheses at Autopsy: An Analysis of 337 Cases with Clinicopathologic Correlation

  • Author/Authors

    Vaideeswar، نويسنده , , Pradeep and Deshpande، نويسنده , , Jaya Ramesh and Sivaraman، نويسنده , , Ammu، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    8
  • From page
    279
  • To page
    286
  • Abstract
    We evaluated the pathologic findings at autopsy in 337 patients who had undergone cardiac valve replacement over 10 years (1982 to 1991). Rheumatic heart disease was the most common indication for valve replacement (84% of cases). Among the 255 patients with short-term survival (<1 month), in 162 cases (63.5%), the cause of death was related to surgery and/or underlying cardiovascular conditions. Host–prosthetic valve interactions contributed to mortality in 14.9% cases. However, in longtime survivors (82 patients), a significant number (86.5%) showed evidence of prosthesis-related complications, such as infective endocarditis, thrombosis, anticoagulant-related hemorrhage, and bioprosthetic valve degeneration.
  • Journal title
    Cardiovascular Pathology
  • Serial Year
    1997
  • Journal title
    Cardiovascular Pathology
  • Record number

    1842692