• Title of article

    Risk factors for late extubation after coronary artery bypass grafting

  • Author/Authors

    Ji، نويسنده , , Qiang and Chi، نويسنده , , Liangjie and Mei، نويسنده , , Yunqing and Wang، نويسنده , , Xisheng and Feng، نويسنده , , Jing Jing Cai، نويسنده , , Jiangzhi and Sun، نويسنده , , Yifeng، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    8
  • From page
    275
  • To page
    282
  • Abstract
    Objective luate the independent risk factors for late extubation after coronary artery bypass grafting (CABG). s rative, intraoperative, and postoperative characteristics of patients undergoing isolated CABG between June 2005 and June 2008 at the Tongji Hospital were retrospectively analyzed. Elapsed time between CABG and extubation of more than 8 hours was defined as late extubation. s cidence of late extubation after CABG was 69.23% (288/416). Through univariate and logistic regression analysis, the independent risk factors for late extubation after CABG were older age (odds ratio [OR] = 4.804), duration of cardiopulmonary bypass (OR = 2.426), perioperative use of intra-aortic balloon pump (OR = 1.451), preoperative arterial oxygen partial pressure (OR = .204), and postoperative hemoglobin level (OR = .793). sion age, prolonged cardiopulmonary bypass time, perioperative intra-aortic balloon pump requirement, low preoperative arterial oxygen partial pressure, and low postoperative hemoglobin level were identified as the 5 independent risk factors for late extubation after CABG.
  • Journal title
    Heart and Lung
  • Serial Year
    2010
  • Journal title
    Heart and Lung
  • Record number

    1859261