Title of article :
Combined Hydrogen, Heat and Power (CHHP) pilot plant design
Author/Authors :
Yu، نويسنده , , Mengjing and Muy، نويسنده , , Suzann and Quader، نويسنده , , Farah and Bonifacio، نويسنده , , Abigail and Varghese، نويسنده , , Roshni and Clerigo، نويسنده , , Elisha and Biery، نويسنده , , Maya and Mei، نويسنده , , Maggie and Cutler، نويسنده , , Dustin and Schoenung، نويسنده , , Julie M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
8
From page :
4881
To page :
4888
Abstract :
The Combined Hydrogen, Heat and Power (CHHP) system consists of a molten carbonate fuel cell, DFC300. DFC300 consumes biogas, and produces electricity and hydrogen. The high temperature flue gas can be recovered for useful purposes. During the hydrogen recovery process, the anode exhaust gas (37.1% H2O, 45.9% CO2, 5.7% CO, and 11.2% H2) is sent through a water gas shift (WGS) reactor to increase the hydrogen and carbon dioxide composition, and then water is removed in a vapor–liquid separator. The remaining hydrogen and carbon dioxide mixture gas is separated using a 2-adsorber pressure swing adsorption unit under 1379 kPa. Resulting hydrogen can achieve 99.99% purity, and it can be stored in composite hydrogen storage tanks pressurized at 34,474 kPa. Hydrogen is produced at a rate of 2.58 kg/h. The produced hydrogen is filled into transportable hydrogen cylinders and trucked to a residential community 7.5 km away from the CHHP site. The community is powered by fuel cells to supply electricity to approximately 51 apartments. A heat recovery unit to produce steam and hot water recovers hot air exhaust from the DFC300, having a total heating value of 405 MJ/h. The greenhouse employs a two-phase steam heating system. Hot water supply is mainly needed for the CHHP education center. DFC300 produces electricity at a maximum capacity of 280 kW. A substation is built to set up the interconnections. Power poles and power lines are built to distribute electricity to the CHHP system, the education center, and the greenhouse. The overall electricity consumption of the CHHP system is 86 kW, and the greenhouse consumes 40 kW. Therefore, an aggregate of 154 kW of power can be used to provide power to the UC Davis campus.
Keywords :
Heat recovery , Tri-generation , Hydrogen power , Hydrogen purification , Heat and Power System , Combined Hydrogen
Journal title :
International Journal of Hydrogen Energy
Serial Year :
2013
Journal title :
International Journal of Hydrogen Energy
Record number :
1862376
Link To Document :
بازگشت